Configuration - Nera WiLink-I Series System Manual

Modular base station
Table of Contents

Advertisement

The default file name is:
Full: backup.res.
¢
Profiles: profiles.res
¢
Profiles and Services: profiles_srvcs.res
¢
Filtering: filtering.res
¢
Traps Configuration: traps_config.res
¢
The file is encrypted and cannot be edited. However, it can be downloaded to other
NPU(s) using a DOS based TFTP Client application with the command: tftp i <Port
IP address> put <file name>.
The target NPU will decrypt the backup file, extract all the configuration files and
databases and will store them, replacing existing files/databases. The NPU should
be reset to apply the downloaded configuration.
NOTE
To avoid loss of connectivity behind a router, the basic IP parameters of the MGMT and DATA ports
(IP Address, Subnet Mask, Default Gateway) are not changed when loading a Full backup file to the
NPU. The values of these parameters configured in the target NPU before the loading process, are
maintained.
4.5.2.6
Monitor Inactivity Timeout
The Monitor Inactivity Timeout parameter determines the amount of inactive time
following which the unit automatically exits the Monitor program.
The time out duration can range from 0 to 60 minutes. 0 means no inactivity
timeout.
The default value is 10 minutes.
4.5.3

Configuration

The NPU Configuration menu enables viewing and updating parameters that
define the functionality of the MGMT and DATA ports, the properties of authorized
management stations and bridging functionality. It also enables configuring per
Telnet session the types of messages that will be displayed upon occurrence of
various events.
The following are the guidelines for configuring these parameters: