Restart After Doglegging - Bauer LINESTAR 9000 Operating Manual

With hose feed
Table of Contents

Advertisement

19.1 RESTART AFTER DOGLEGGING

NOTE!
WARNING!
Put switch "SAFETY CIRCUIT ON - OFF" to „OFF"
Put switch "LINESTAR OFF - ON" to „ON"
Control panel LINESTAR PRO / PRO-G
The control panel displays mode "ALIGNING"
Press "FORWARD" or "REVERSE" key to select the travel direction which is necessary to bring the outer spans
back to form a straight line with the system.
That is:
the outer doglegging towers hurry ahead: press the „REVERSE" key.
the outer doglegging towers lag behind: press the „FORWARD" key.
Press and hold the „+" key, the end tower is moving as long the „+" key is held.
Press and hold the „-" key, the central unit is moving as long as the „-" key is held.
Hold the „+" or „-" keys until the misaligned spans are properly re-aligned.
Check travel direction when spans start moving. In case of wrong direction release key at once.
Press keys "R" or "F" to activate the tower alignment switches (for manual alignment at tower - concerns alignment
control units with tower alignment switch)
CAUTION!
NOTE!
NOTE!
CAUTION!
As soon as the towers are re-aligned (forming a straight line) and the inward towers also start to move, release the
"+" or the "-" key.
Put the safety circuit switch to "ON".
NOTE!
Test proper moving of the LINESTAR by a short touch of the "FORWARD" or „REVERSE" key.
Operating Manual for BAUER LINESTAR 9000 with hose feed
Before carrying through the below mentioned operations be sure to rectify the cause
of doglegging (cf. chapter Troubleshooting).
In the "OFF" position, the "SAFETY CIRCUIT" switch deactivates the safety system.
Only permitted for service works.
Selecting the proper running direction ensures that only the outer misaligned towers
start moving when the drive is turned on.
The wrong running direction will cause impermissibly high stress on the trussing.
The towers only move as long as you hold the "+" or "-" key..
The inward towers may start moving for a short time after the start-up
Continuously check tower movement after the start in order to be able to stop the
system again immediately should the doglegging continue (Release "+" or " -" key).
Operating the BAUER LINESTAR with "SAFETY CIRCUIT SWITCH turned to "OFF"
is only permitted for system alignment.
57