WARNING !
Control panel LINESTAR PRO / PRO-G
The control panel displays mode "ALIGNING".
Press "FORWARD" key
Press "+" and "-" keys simultaneously and hold the keys. The LINESTAR must start to move clockwise.
Press "REVERSE" key.
Press "+" and "-" keys simultaneously and hold the keys. The LINESTAR must start to move anti-clockwise.
In case of faulty run of the system release the "+" and "-" keys immediately!
In case the travel direction of the wheel pairs of the central tower do not harmonize, shut off of electric power
supply and change 2 phases of the feeding cable on the main switch.
If none of the towers starts correctly into the set travel direction, shut off of electric power supply and change 2
phases of the feeding cable on the main switch
If only individual towers travel into the wrong direction, shut off of electric power supply and reverse the poles of
the motor supply cable at the concerned tower.
15.6 ALIGNMENT OF THE TOWERS
If the system is not precisely aligned after mounting, i.e. the assumed connecting line of all drive motors does not
form a perfect straight line, the system needs to be aligned as follows:
In order to prevent a mechanical overload of the truss, align the Linestar step by step
NOTE!
starting at the system end. The assumed line connecting all tower motors with the
middle of the central tower must be perfectly straight.
Start generator unit
Turn main switch to position "1"
Turn "safety circuit" switch to "OFF"
Turn „LINESTAR OFF-ON" switch to "ON"
Control panel LINESTAR PRO / PRO-G
The control panel displays mode "ALIGNING".
Press "FORWARD" or "REVERSE" key to select travel direction
Press "+" key. As long as the "+" key is hold the end tower is moving.
Press "-" key. As long as the "-" key is hold the central tower is moving.
Press "+" and "-" keys simultaneously to make run both central tower and end tower. They will continue to move
as long as the +- keys are hold.
Align the towers by the tower alignment switches to make them form a straight line with the middle of the central
tower (aiming over drive motor).
In order to prevent a mechanical overload of the truss, align the Linestar step by step
NOTE!
starting at the system end. The assumed line connecting all tower motors with the middle
of the central tower must be perfectly straight.
15.7 ALIGNMENT CONTROL ADJUSTMENT
40
In the "OFF" position, the "SAFETY CIRCUIT" switch deactivates the safety system.
Operating Manual for BAUER LINESTAR 9000 with hose feed