Setting Linear Control; Furrow And Cable Guidance - Bauer LINESTAR 9000 Operating Manual

With hose feed
Table of Contents

Advertisement

The conductor must be laid in a depth of 70 cm to 90 cm, depth which depends on the local conditions. Normally it
is given by the customer.
For more detailed information about laying of the cable, see the CABLE LAYING INSTRUCTIONS FOR BELOW
GROUND GUIDANCE under separate cover.

10.6 SETTING LINEAR CONTROL

10.6.1 FURROW AND CABLE GUIDANCE

Before starting, adjust the linear control system such that the central tower will run parallel to the guiding cable or to
the guiding furrow in both directions.
The setting of the switch points for furrow and cable guidance is basically the same.
Position the central unit in relation to the cable or the furrow in such a way, that both control arms, when they
are in their operating condition (rollers on the cable or in the furrow) form a straight line with the fixed control
frame of the central unit.
Loosen the fixing screw on the control rod, which actuates the control cam of the control system. The control
rod moves freely on the guide pin.
By moving the control rod hence and forth, the switching points of the micro-switches are determined. Every
micro-switch has two switching points, a switch-on point and a switch-reverse point. Each of these switching
points is marked on the guiding pin. Fix the switching points according to the following figure:
28
Operating Manual for BAUER LINESTAR 9000 with hose feed
skid or cable roller

Advertisement

Table of Contents
loading

Table of Contents