9.1.1.3 VOLTMETER
Indicates the voltage between phases L1 and L2.
9.1.1.4 SWITCH "LINESTAR OFF-ON"
Establishes power supply of control panel. In the "ON" position, the system can be started or stopped with an
operation on the LINESTAR PRO control panel.
9.1.1.5 SWITCH SAFETY CIRCUIT ON-OFF"
If this switch has been put to position "ON", the whole system will be shut down in case of malfunction
(misalignment). The position "OFF" is only to be used by an expert person for system alignment.
Whenever the machine is running the switch must be in position "ON" in order to guarantee a safe
unattended run!
9.1.1.6 SWITCH "END GUN OFF-ON"
In position "ON" the end gun is in use, in position "OFF" it is out of use.
9.1.1.7 SWITCH "GENERATOR OFF-ON"
The generator unit shuts down automatically.
ON
when system runs into safety circuit.
in case of pressure loss in supply line
at end stop
at intermediate stop, e.g. when changing the connection of the supply hose.
Use this setting for regular run!
OFF
In this position the generator unit does not shut down automatically for the above mentioned reasons.
This setting is used for:
aligning the LINESTAR
dry run of LINESTAR
9.1.1.8 SWITCH "EMERGENCY STOP"
Control unit is cut off power
Operating Manual for BAUER LINESTAR 9000 with hose feed