If the distance between the end switching points of both micro-switches is too small or too great, readjust the
position of the micro switches and verify the distance between the switching points.
If the distance between the switching points is correct, the control rod must be fixed exactly in the centre
between the switching points.
Set the second linear control system the same way.
10.6.2 BELOW GROUND GUIDANCE
Before starting, ensure that the antennas of the below ground guidance are properly mounted and adjusted.
In this regard, also read 12 ALIGNMENT OF THE LINESTAR and 15 FIRST START-UP.
10.7 SETTING STOP SWITCH
There are switches on the central tower of the LINESTAR, which stop the system.
To activate these switches, actuation pegs must be provided along the track.
Operating Manual for BAUER LINESTAR 9000 with hose feed
29