11 DIESEL GENERATOR UNIT

For the supply of the electric drive and control system of the LINESTAR a diesel generator unit is mounted on the
central unit. Depending on the power requirement of the system the electrical power of the unit is between 10kVA
and 20kVA.
The unit is complete and consists of the following components:
Base frame with integrated fuel tank.
Diesel engine with electric start including battery
Generator directly coupled to the engine.
Unit cover
Unit control panel with following functions and indications:
Three Ampere indicators (one per phase)
One voltmeter with phase converter
Frequency indicator
Operating hour meter
Luminous indication of malfunction
Failure indicator for oil pressure, cooling water temperature, battery charging, fuel,
Warning siren
Fuses
Start lock with key
Stop switch

12 ALIGNMENT OF THE LINESTAR

12.1 ALIGNING THE CENTRAL UNIT PARALLEL TO THE LINEAR GUIDANCE
(FURROW, CABLE)
Operating Manual for BAUER LINESTAR 9000 with hose feed
Schalter f. Zwischenstopp
switch f. intermediate stop
Schalter f. Endstopp
switch f. end stop