Outward
Direction last tower
Positive bow hurrying ahead
If the middle towers are in front of an assumed straight line in travel direction between central tower and end tower.
Negative bow hurrying backward
If the middle towers are behind an assumed straight line in travel direction between central tower and end tower.
Dogleg
Happens, when a tower gets slower or stands still or hurries ahead of the other towers.

17 START-UP

The LINESTAR is only to be released for operation to the customer after it has been completely assembled,
installed and successfully started up by a qualified person!
As the machine is operated with voltages from 230 V up to 460 V, the control components and the electric drive
need to be handled with the utmost caution! Service and repair works must imperatively be done by a professional
electrician!
Before starting the system make sure, that all connected devices (like generator and pump units) are ready for
operation. Have the responsible service centre repair possible damages, before you start irrigating. Be extremely
cautious with live parts.
The start-up as described below is valid for a BAUER LINESTAR 9000 without optional equipment. If the system
has got any optional equipment (see chapter options), it has to be set properly and turned on before the start-up.
If you have purchased a LINESTAR with Below Ground Guidance, be sure that the oscillator box is supplied with
voltage. With a 230V AC supply, put the main switch of power supply to position "1". With a 24V DC battery supply
(2 x 12V DC), check if the batteries are connected and sufficiently loaded.

17.1 START LINESTAR IN OPERATING MODE "LINEAR"

17.1.1 START LINESTAR WITH HOSE FEED

 Connect supply hose to hydrant and central tower, open water supply
 Put switch Genset „OFF – ON" to „OFF"
 Start generator unit
 Turn main switch to „1"
 Put switch "LINESTAR OFF - ON" to „ON"
 Put switch "SAFTEY CIRCUIT ON – OFF" to „ON"
 Put switch "END GUN OFF - ON" to "ON"
 Control panel LINESTAR PRO / PRO-G
 Press key "ENTER (MENU)", the cursor starts blinking
 Select mode "LINEAR" with "+/-" keys.
 Press „FORWARD" key to go to parameter travel length, set travel length with "+/-" keys
 Confirm with „ENTER" key
 Exit programming mode with „ESC" key.
 Press „FORWARD" or „REVERSE" key depending on running direction
 Modify application rate with "+/-" keys.
 Put switch "GENSET OFF – ON" to „ON"

17.2 STARTING AFTER INTERMEDIATE STOP