18.2 SERVICE PLAN

Central unit
Check all screwed joints
Check tightness of electric cable entries into the control centre
Check tightness of connecting hoses in the riser pipe
Trussing, overhang, coupling
Check all screwing on flanges, truss rods, braces, on towers and on overhang
Check tightness of connecting hose at tower couplings.
Lubricate ball joint of tower couplings
Empty sand trap
Booster pump – spinning of shaft between engine and pump – check if pump rotor rotates
freely (if existing)
Check end gun (if existing)
Tower box, transmission device
Check switch cam and adjust if necessary
Check shifting travel of micro switches
Check function of micro switches (operation switch and safety switch)
Check all electric connections for contact
Check tightness of all cable entries into the alignment control
Check tightness of alignment control covers
Lubricate the ball joints at transmission parts
Exact control – Check tension of guiding cables
Visual inspection of span alignment
Check function of switches for intermediate stop, end stop and of programme switch