Shut-Down Procedure; System Shut Off During Irrigation; Automatic Systemm Shut Off At Field End; Starting Linestar To Run In Opposite Direction After An Automatic Shut-Down - Bauer LINESTAR 9000 Operating Manual

With hose feed
Table of Contents

Advertisement

It may be necessary to stop the LINESTAR somewhere along an irrigation strip, for instance if the supply hose
needs to be connected to another hydrant or if only a partial area has to be irrigated.
In this case a shut-down sensor is actuated by a switching peg and the machine is turned off.
The shut-off valve in the riser pipe (option) is closed and the generator unit is shut down, when the switch
"GENSET OFF-ON" has been put to "ON".
Control panel LINESTAR PRO / PRO-G
 Press "Forward" or "Reverse" key
 The machine must leave the switching range within 30 seconds, otherwise it will be shut off automatically.

17.3 SHUT-DOWN PROCEDURE

17.3.1 SYSTEM SHUT OFF DURING IRRIGATION

Control panel LINESTAR PRO / PRO-G
 Press "ESC – STOP" key
If the switch GENSET "OFF-ON" has been turned to "ON", the generator unit shuts down automatically. If the
switch has been turned to "OFF", the generator unit must be turned off separately. Water supply will be cut
automatically by the shut-off valve.

17.3.2 AUTOMATIC SYSTEMM SHUT OFF AT FIELD END

The switches of the central unit shut the LINESTAR automatically down, when they are actuated by the end
stoppers which have been placed at the end of the field.
If the switch "GENSET OFF - ON" has been put to „ON", the generator unit shuts down automatically. If the switch
has been turned to „OFF" the generator unit must be shut down separately
The water supply is cut automatically by the shut-off valve
17.4 STARTING LINESTAR TO RUN IN OPPOSITE DIRECTION AFTER AN
AUTOMATIC SHUT-DOWN
 Put switch "GENSET OFF - ON" to "OFF"
 Start generator unit
 Establish water supply
 Put switch "SAFETY CIRCUIT ON - OFF" to "OFF"
 Control panel LINESTAR PRO / PRO-G
 The control panel displays mode "SETTING"
 Press the "FORWARD" or „REVERSE" key to select travel direction
 Press and hold the "+" and "-" keys simultaneously until the machine has left the switching circuit
 Put switch "SAFETY CIRCUIT ON - OFF" to "ON"
 Control panel LINESTAR PRO / PRO-G
 Press „FORWARD" or „REVERSE" key to start the machine
 Put switch "GENSET OFF - ON" to "ON"