18.3 POST-SEASON MAINTENANCE

1.
Remove the drain valves and plugs in the pipeline.
2.
Open gate valve of sand trap.
3.
Flush the pipelines.
4.
Remount and close drain valves, plugs and gate valves at sand trap.
5.
Remove the supply hose from the irrigation field and stock it in a building.
6.
Empty the coolant of the generator unit or care for sufficient anti-freeze.

18.4 PRE-SEASON MAINTENANCE

1.
Check control centre and alignment controls for damages due to oxidation, rodents and insects.
2.
Open sand trap gate valve and flush pipelines.
3.
Check tightness of flange seals and connecting hoses.
4.
Close sand trap gate valve.
5.
Tension cable for cable guidance and align pegs
6.
Draw a new furrow for the furrow guidance
7.
Place and align the pegs correctly for intermediate stop and end stop
8.
Unwind supply hose and check if it is still waterproof
9.
Fill in or add coolant into the generator unit. Check motor oil.
10.
Further checks => CHECKLIST
11.
Optional: For below ground guidance, connect the power supply for the oscillator box or mount and
connect the battery.