9 - 2 REPLACING THE VOLUME
Be sure to turn the power off first, before performing work, and avoid touching
unspecified places. Failure to do so can cause electric shock and/or short circuit.
1
Remove the Volume Gear from the Volume to replace the Volume.
2
After replacing the Volume, make adjustments as per 11-1 ADJUSTING THE VOLUME.
9 - 3 GREASING
Be sure to turn the power off first, before performing work, and avoid touching
unspecified places. Failure to do so can cause electric shock and/or short circuit.
Be sure to use the designated grease. Using undesignated grease can cause parts
damage
Do not apply greasing to undesignated places. Doing so can cause malfunctioning
or quality deterioration of parts.
Apply greasing to the following portions once every three (3) months.
For Spray Grease, use NOK GLUBER L60 or GREASE MATE (Part No. 090-0066).