8. CONTROL MECHA

Be sure to turn power off before performing work, and avoid touching undesignated
places. Failure to do so can result in electric shock and short circuit accidents.
Be careful so as not to damage wirings. Damaged wiring can cause electric shock
and short circuit hazards.
When performing work, be sure to use 2 or more persons. One person alone per-
forming work can cause accidents and parts damage.
In the test mode, if the CONTROL HANDLE's VR variations are not within the allowable range, then a VR
installation position adjustment or VR replacement is needed. Also, be sure to apply grease to the VR gear
portion once every 3 months.

8 - 1 REMOVING THE CONTROL MECHANISM

1
Turn the power switch off.
2
Remove the 3 Hexagon Socket Bolts from the lower part of the Control Panel.
3
Remove the 4 Tamperproof Screws from both sides of the control panel's front
4
Remove the 3 Tamperproof Screws from the underside of the control panel.
5
Carefully draw out the Control Mechanism in a mnner so as not to damage wiring and connectors inside the
control panel..