Table of Contents

Advertisement

11 . COIN SELECTOR

HANDLING THE COIN JAM
If the coin is not rejected when the REJECT BUTTON is pressed, open the coin chute door
and open the selector gate. After removing the jammed coin, put a normal coin in and check
to see that the selector correctly functions.
CLEANING THE COIN SELECTOR
The coin selector should be cleaned
once every 3 months. When cleaning,
follow the procedure below:
Turn the power for the machine OFF.
1
Open the coin chute door.
Open the gate and dust off by using a
2
soft brush (made of wool, etc.).
Remove and cleen smears by using a
3
soft cloth dipped in water or diluted
chemical detergent and then squeezed
dry.
Remove the CRADLE.
4
When removing the retaining ring(E-
ring), be very careful so as not to bend
the shaft.
Remove stain from the shaft and pillow
5
portions by wiping off with a soft cloth,
etc.
After wiping as per #5 above, further
6
apply a dry cloth, etc. to cause the coin
selector to dry completely.
Never apply machine oil, etc. to
the coin selector
After cleaning the Coin Selecting,
Insert a regular coin in the normal
working status and ensure that
the Selector correctly functions
COIN INSERTION TEST
Once a month, when performing the COIN SW
TEST, simultaneously check the following:
Does the Coin Meter count satisfactorily?
Does the coin drop into the Cashbox correctly?
Is the coin rejected when inserted while keeping
the REJECT BUTTON is pressed down?
.
Insert a coin
while keeping
the Reject
Button pressed
down and check
if it is
rejected.
COIN METER
GATE
FIG. 11a
CRADLE
FIG.11b
FIG. 11c