Sequence of operations Read the chapter 7.1. Functions of the push-buttons during
Function
Sequence of operations Read the chapter 7.1. Functions of the push-buttons during
Notice
36

7.7. Menu item 03: Decimal point position

Setting the position of the decimal point on the display, or switching
the decimal point off.
[Default factory setting: 2 decimals]
navigation in the menu for learning the buttons handle.
1. Enter the menu by typing the supervisor code.
2. Keep stepping by pressing the ▲ button as long as you see this
menu item.
3. Enter the menu item by pressing the Menu button.
4. Pressing the ▲ button, select the desired value.
5. Exit from menu item by pressing the Esc button. The change is
saved to FRAM.
(6. Press Esc button again if you want to leave the menu.)
The selectable values: 2, 1, 0, 4, 3.

7.8. Menu item 04: Low value of scale

Any optional display range can be assigned to the input signal range
(scaling). Here you can set the low value of the desired display range.
[Factory default: 000.00. ]
Note! For scaling the DISPLAYED value you should set the high value
also. (Next menu item.)
navigation in the menu for learning the buttons handle.
1. Enter the menu by typing the supervisor code.
2. Keep stepping by pressing the ▲ button as long as you see this
menu item.
3. Enter the menu item by pressing the Menu button.
4. Type the desired value by using the ▲ and the ► buttons.
5. Exit from menu item by pressing the Esc button. The change is
saved to FRAM.
(6. Press Esc button again if you want to leave the menu.)
For scaling must be assign the high (end) value also. (Next menu
item)
DT4220 E
20180619-V0