Advanced Mode

Provides a 3-tier PIN code system for commercial use. In Advanced mode, a total of 1,000
PIN codes are available for access. The 1,000 PIN codes are divided into twenty (20)
Supervisor groups of fifty (50) User codes per group.
Advanced mode also has a Master code which is used only for programming and does not
grant access.
Master
Supervisor
Supervisor
00
04
User
01
User
02
User
03
User
48
49
User
Settings
Entrance Authorization
Register/Change Master Code
Register/Change/Delete Supervisor Code
Register/Change/Delete User Code
Set All Code Lockout Mode
Set Group Lockout Mode
Set User Lockout Mode
Set Passage Mode
Set Silent Mode
Set Re-lock Time
Set Wrong Code Entry Limit
Set Shut Down Time
Set Language Setting Mode
Operation of Lock
Touch lock with palm
of hand or fingers
to activate.
An ASSA ABLOY Group brand
Supervisor
19
Supervisor
09
User
01
01
User
02
02
User
03
03
User
48
48
49
User
49
Master
Supervisor
x
x
x
x
x
x
x
x
x
x
Enter PIN code.
ƒ All programming is performed through the
touchscreen by use of the Master code or
Supervisor code and voice guided prompts. Only
the Supervisor code can establish User codes.
ƒ While in Advanced mode, the lock can be
programmed for Passage mode, Silent mode,
User
Lockout mode or alternate Language settings.
User
Auto re-lock time, wrong code entry limits and
shut down times are adjustable can be changed
User
from factory default.
ƒ The operating mode can be changed from
Advanced to Easy or visa versa for any lock.
User
Changing the mode resets the lock to factory
defaults and all prior programming and PIN
User
codes will be lost. See page 17 for more
information.
User
Master Code
x
x
Lockout Mode
Passage Mode
Silent Mode
x
Re-lock Time
Wrong Code Entry Limit
x
Shut Down Time
x
x
Language
x
Palm or touch the
to confirm the selection.
Settings
Factory Defaults
123456
Disabled
Disabled
Disabled
5 Seconds
5 Times
180 Seconds
English
Turn lever to
key
open door.
P/N 80-9150-0065-010 Rev B
14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Yale inTouch and is the answer not in the manual?

Questions and answers

Table of Contents