Trigger operation and timing chart

1. Normal mode
Shutter time
Data output
VD
FVAL
*1:When partial scan, variable by setting.
*2:When partial scan, variable by start position of picture grabbing.
*3:When partial scan, variable by set width of picture grabbing.
Graph following shows frame rate in each of picture grabbing in the partial scan mode.
70
60
50
40
30
20
10
0
Shutter time
(Camera setting value)
10H (*1)
3H
KP-F500PCL/SCL Partial scan
0
500
8H (*2)
2058H (*3)
1000
Width of picture grabbing [H]
Note: Please ask your sales representative more detail information
about frame rate in each width of picture grabbing.
5H when vertical two pixel addition.
4H when vertical two pixel addition.
1029H when vertical two pixel addition.
1500
2000
23