Explanation:2 ≤ n ≤ 6(the other value of n is invalid). Set the horizontal module width of
barcode. The detail is as below,
n
Width of single basic
module (mm)
2
0.25
3
0.375
4
0.5
5
0.625
6
0.75
Single basic module barcode:UPC-A, UPC-E, JAN13 (EAN13), JAN8 (EAN8), CODE93,
Double basic module bar code:CODE39, ITF, CODABAR
Default value:n = 3. Pls refer to GS k。
Width of double basic module
Narrow
basic
module (mm)
0.25
0.375
0.5
0.625
0.75
CODE128
46
Wide
basic
module(mm)
0.625
0.875
1.25
1.625
1.875
Need help?