Verifying Hardware - Avaya S8700 Series Manual

Migrating
Hide thumbs Also See for S8700 Series:
Table of Contents

Advertisement

Install the Avaya S8710 Media Servers either
- in a 19-inch, 4-post rack as described in the Quick Start for Hardware Installation: Avaya
S8700 Series Media Servers (555-245-703).
- on a pullout shelf attached to the existing 2-post rack.
Install the current software on the S8710 Media Servers.
Restore the Linux migration upgrade set from the customer's network to both S8710
Media Servers using the Linux Migration (Backup/Restore) link.
Note:
If moving Ethernet switch(es) and UPSs to the 4-post rack, do it here before the
Note:
cutover.
Connect the control network Ethernet cables to the new S8710 Media Servers, standby
media server first.
Connect the duplication cables after restoring files to the second media server.
Complete the post-migration administration.

Verifying hardware

You can reuse some of the equipment and cables when migrating a S8700 Media Servers to
S8710 Media Servers; see
complete the migration; see
Table 13: Reusable hardware 1 of 2
Comcode
408357002
408427409
700181928
108873233
108563123
108644451
700169121
700170012
700178056
700178064
Reusable hardware
Required new hardware
Description
Powerware 9125 uninterruptible power supply (UPS)
with SNMP adapter installed (if Avaya-provided)
– US & Canada
– International
– Japan
10/100BaseT Ethernet switch (if Avaya-provided)
– Avaya Ethernet P133 switch
– Avaya Ethernet P333 switch
– Avaya Ethernet P334 switch
External V.90 56K USB modem with cable (if used)
Green CAT5 Ethernet cables
– 5-meter (16 feet)
– 25-meter (82 feet)
– 50-meter (164 feet)
on page 155. But you need new equipment to
on page 156.
Issue 4 January 2005
Pre-Migration Setup
Quantity
2
1 or more
2
4
2-68
2-68
1 of 2