Site Preparation; Thermomasseur ® Installation - BainUltra THERMOMASSEUR Owner's Manual

Hide thumbs Also See for THERMOMASSEUR:
Table of Contents

Advertisement

THERMOMASSEUR
FAUCET INSTALLATION
• S ee the manufacturer's technical specifications for
faucets location and plan the water supply accordingly.
• Position drain according to manufacturer's
specifications.
BEDDING
Before installing, ensure that the floor underneath the
bath can support 1,500 lbs (680 kg). The bath may sit
directly on the floor. However, the bath may also be
installed on a bed of concrete. For this type of instal-
lation, it is recommended that you insulate the con-
crete between two sheets of plastic, one on floor and
the other underneath bath.
SERVICE ACCESS AND VENTILATION
• A service access is necessary. Minimum dimensions
are: 22" x 18" (55 cm x 46 cm) to properly reach all
electrical components of the system.
• An air vent is also necessary. Minimum dimensions
are: 2" x 4" (5 cm x 10 cm) to ensure proper function-
ing of the turbine. The service access panel is often
the best place to install the air vent.
ISLAND TUB DRAIN
• The ITD is strongly recommended when you have no
access under the floor.
6
OWNER'S MANUAL | INSTALLATION INSTRUCTIONS
®

SITE PREPARATION

1 800 463.2187
Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
TECHNICAL SPECIFICATIONS
There is a technical specification sheet for each
BainUltra ThermoMasseur
tion such as necessary dimensions of site before
installation.
If you do not already have the technical specifica-
tions, download it from BainUltra
bainultra.com or call us at: 1 800 463-2187.
TURBINE - REMOTE INSTALLATION
• A 1 ½ inch ID pipe has to run from the tub, back to
the turbine location. This pipe can be PVC Tigerflex
(spa hose) or rigid PVC or ABS
• Maximum distance is 15 feet from the tub, indoors,
in a room temperate setting (not outdoors or in a
non-temperature controlled area)
• Minimum size for an enclosure for the turbine: 16'' x
16'' x 16''
• Make sure to leave access for servicing needs
• The enclosure should have a minimum 4x2 inch
opening so the turbine works properly. Not doing so
will starve the blower of air. It will eventually fail and
void its warranty
• A 20 Amp GFCI (12AWG) 120V dedicated line is
needed for the turbine (GeysAir is powered by the
turbine). If you have additional options on the bath
(one or more) a second dedicated line is needed, 15
Amp GFCI 120V (14AWG).
See page 24 for detailed instructions.
Printed in Canada. Copyright © June 2020 BainUltra Inc. All rights reserved. 45200001