TROUBLESHOOTING | OWNER'S MANUAL
SITUATION
Air jets are cool.
Jets are too hot.
Chromatherapy
lights don't work.
www.bainultra.com
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
Temperature of air injected into bath is directly proportional to the speed of the
turbine. The higher the speed, the warmer the air is. A simple way to check if your
air-heater or heaters are working properly is to turn on the system at the high-
est speed (if your control offers a range of intensities) with no water in the bath
(there is absolutely no risk to the system). After 3 to 5 minutes, the heated back-
rest or backrests should be warm to the touch and jets should also seem warm
when you bring your hands close to them.
• Check the turbine air intake. It should not be too cold nor too warm. Ideally, the
temperature should be between 72°F (20°C) and 86°F (30°C).
• Check that distance between turbine and bath is not too great. If possible,
insulate air line along its entire length. See turbine installation section of this
manual.
Bath with Geysair
• The Geysair option is not activated on the control panel.
• The Geysair hot water supply hose is not connected.
• The Geysair hot water supply hose is connected to a cold water supply.
• The hot water hose is too long or not properly insulated.
• The Geysair intensity regulator is obstructed.
• For any remote installation, the turbine and the Geysair are not
properly connected.
• I f using a tankless water heater, insure minimum water flow activation is ad-
equate.
• I f minimum flow activation of your tankless water heater is higher than 0.13
GPM, have a recirculating loop installed by a certified plumber or install a point
of use water tank (2,5 gallons for example) dedicated to Geysair.
• Deactivate the Geysair option, if applicable.
• If the Geysair option is installed on the bath, lower the temperature
of the water heater.
A LED has a 100 000-hour lifecycle.
• Verify wiring and connections.
• U nplug and plug again LED module power supply. You should see a light flash
in every LED. If not, check your power source. If LED flash but still don't work,
please call BainUltra.
TROUBLESHOOTING