TURBINE

REMOTE MOUNTING INSTALLATION

LOCATION
Choose a location not requiring more than six
elbows (directional changes) and 15 ft. (4.6
m) of piping to the bath. Choose the shortest
possible distance between bath and turbine
to insure the system's performance. Sufficient
space and ventilation is necessary for proper
air circulation. Ambient air temperature should
be between 72°F (20°C) and 86°F (30°C). Easy
access to system must remain possible at all
times for servicing.
TURBINE INSTALLATION
Turbine may be relocated in either a vertical or a
horizontal position.
Use only 1 1/2" (3.8 cm) ABS or PVC non-
flexible pipes and adaptors to extend air line;
the use of flexible pipes is not recommended
(except when factory-installed). Whenever
possible, use two 45° elbows to change the
direction of your piping. All air line pipe con-
nections should be glued together except for
connections to the turbine, air-heater of the
double heated backrest of the Amma
air entry on the bath which are secured in place
with screws.
The turbine must be mounted at least 4" (10
cm) from the floor. To reduce heat loss, use
insulating material along the entire air line. Bath
is delivered with a 15 ft. (5 m) cord to connect
the electronic control to the turbine. If neces-
sary, extensions are available through a retailer.
To relocate turbine, refer to directions and illus-
trations on following pages.
IMPORTANT
• Geysair should never be installed remotely.
• If the ThermoMasseur
system (optional), InMix module and Litestreme module must always be moved with the turbine.
WARNING
• A waiting period of 24 hours is necessary before using turbine if pipes have been glued together.
24
OWNER'S MANUAL | TURBINE ELECTRICAL INSTALLATION
All bath components are factory-installed. If you wish to
relocate the turbine and InMix module (Chromatherapy) for
practical or accessibility reasons, follow these instructions.
Failure to follow these instructions could result in serious
personal injury or and/or property damage. Failure to follow
these instructions will void the warranty for the Thermo-
Masseur
damage, loss, cost, expense or liability relating to failure to
follow these instructions.
serie and
®
comes with LED Chromatherapy system (optional) or WarmTouchShell
®
1 800 463.2187
Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST)
and BainUltra shall not be responsible for any
®
Printed in Canada. Copyright © June 2020 BainUltra Inc. All rights reserved. 45200001

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents