ELECTRO FREEZE SOFT SERVE TWIST SL500 Operator's Manual page 43

Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Model SL500
12
Trouble Shooting Tables
PROBLEM
Unit does not
1.
operate.
2.
3.
4.
5.
6.
7.
Leakage of mix
1.
or w ater from
drain tube to drip
tray.
2.
3.
Compressor
1.
does not operate
or operates
2.
improperly.
3.
4.
34
PROBABLE CAUSE
Freezer unplugged.
Fuse or breaker blown at main
disconnect.
Beater motor out on overload.
Off on high pressure cut-out control.
Off on low pressure cut-out control.
Faulty selector switch.
Disconnected or broken wire in electrical
circuit.
Damaged beater shaft seal or installed
improperly.
Beater shaft pitted or damaged.
Beater shaft end play not set properly.
Faulty head o-ring.
Head not properly installed.
Faulty contactor.
Disconnected or broken wire in switch.
(continued)
1.
Plug in freezer.
2.
Make sure your freezer is connected to a
separate circuit independent from any
other electrical equipment. Have
technician check fuse or breaker size and
check voltage; if not within 10% of
nameplate rating call power company.
3.
Press overload reset button. Check
product temperature an overrun.
4.
Refer to Troubleshooting Table –
Discharge pressure too high.
5.
Contact your Electro Freeze distributor for
service.
6.
Contact your Electro Freeze distributor for
service.
7.
Contact your Electro Freeze distributor for
service.
1.
Replace cup seals on washer. Install
properly.
2.
Replace beater shaft.
3.
Contact your Electro Freeze distributor for
service.
1.
Replace o-ring.
2.
Install head properly. Replace o-ring if
pinched.
3.
Contact your Electro Freeze Distributor for
service.
4.
Contact your Electro Freeze Distributor for
service.
REMEDY