DISPLAY WARNINGS

Warning
HEAT SENSOR GROUP OPEN ON GROUP #
CHECK THE GROUP HEATING CIRCUIT ON
GROUP #
THE WATER HEATING PROBE IS OPEN ON
GROUP #
CHECK THE WATER HEATING PROBE ON
GROUP #
THE STEAM HEATING UNIT SENSOR IS
OPEN
STEAM HEATING UNIT HEATING CIRCUIT
CUP WARMER SENSOR
STEAM WAND SENSOR
STEAM HEATING UNIT HEATING TIMEOUT
GROUP HEATING TIMEOUT ON GROUP #
GROUP HEATING IS OUT OF SERVICE ON
GROUP #
COFFEE WATER HEATING TIMEOUT
ONGROUP #
58
72
of
Cause
Group temperature probe is disconnected or faulty.
The group heat circuit is open.
The group heating element has stopped.
The safety thermostat is open.
Fuse F5/F6 has burned out.
The Triac is faulty.
The group temperature probe is disconnected or
faulty.
The group water heating circuit is open.
The group water heating element has stopped.
The safety thermostat is open.
Fuse F2/F3 has burned out.
The Triac is faulty.
The steam heating unit temperature probe is
disconnected or faulty.
The steam heating unit heating circuit is
disconnected.
Fuse F7 has burned out.
The static relays are faulty.
The heating element is faulty.
The cup warmer temperature probe is disconnected.
The temperature probe has short-circuited.
The cup warmer has overheated.
The steam wand temperature probe is disconnected.
The steam wand probe has short-circuited.
The steam wand probe has overheated.
The steam heating unit heating circuit is
disconnected.
The safety thermostat is open.
Fuse F7 has burned out.
The group heating circuit is disconnected.
The group heating element has stopped.
The safety thermostat is open.
Both fuses F6 & F5 are burned out, or maybe just one.
The group heating circuit is disconnected.
The group heating element has stopped.
The safety thermostat is open.
Both fuses F6 & F5 are burned out, or maybe just one.
The group water heating unit heating circuit is
disconnected.
The group water heating unit heating element has
stopped.
The safety thermostat is open.
Fuses F2, F3, F8 & F9 have burned out or maybe just
one or some of them.
Action
Check the probe connection and replace it, if
necessary.
Check the group heating circuit: group heating
element; safety thermostat; fuse and triac in the
control unit; main switch; connection of the phases
for the 380 V version.
If necessary, replace the faulty components.
Check the connection and if necessary replace the
probe.
Check the group heating circuit: group heating
element; safety thermostat; fuse and triac in the
control unit; main switch; connection of the phases
for the 380 V version.
If necessary, replace the faulty components.
Check the connection of the steam heating unit
probe and if necessary, replace it.
Check the steam heating unit heating circuit and if
necessary, replace the faulty parts.
Check the cup warmer probe connection and if
necessary, replace it.
Check the steam wand probe connection and if
necessary, replace it.
Check the steam heating unit heating circuit and if
necessary, replace the burned parts.
Check the group heating circuit: group heating
element; safety thermostat; fuse and triac in the
control unit; main switch; connection of the phases
for the 380 V version.
If necessary, replace the faulty components.
Check the group heating circuit: group heating
element; safety thermostat; fuse and triac in the
control unit; main switch; connection of the phases
for the 380 V version.
If necessary, replace the faulty components.
Check the group water heating unit heating: heating
element; safety thermostat; fuses and triacs in the
control unit; main switch; connection of the phases
for the 380 V version.
If necessary, replace the faulty components.