9.3.7
Viewing the warnings
THE last 8 warnings detected by the machine can be
viewed.
Select the
Counters
Counters
Coffee total
00000000
Wash Tot.
000000
Scroll through the various screens with the arrows
( ) or ( ), until you see the screen below:
Warning register
Warning
Date of last
code
occurrence
The screen shows the last eight warnings stored by
the machine.
The alongside table provides a description of each
warning code.
Code Warning description
01
heating unit fillingup timeout warning
02
03
04
heating unit heating timeout warning
05
cup warmer NTC probe open warning
06
cup warmer NTC probe s/c warning
07
water filter max. litres warning
08
steam wand NTC probe open warning
09
steam wand NTC probe s/c warning
10
11
heating unit electronic pressure switch not active warning
12
excessive pressure in the heating unit warning
TECHNICIANS manual
button;
Code Warning description
13
mains electronic pressure switch not active warning
14
excessive mains pressure warning
15
no impulses from group 1 warning
16
no impulses from group 2 warning
17
no impulses from group 3 warning
18
no impulses from group 4 warning
To reset the warnings on the display, proceed as
follows:
Press the reset button (
In the next screen answer "Yes";
All warnings will be reset.
Reset counters.
Are you sure?
Yes
The warnings can ONLY be viewed and reset by the technician.