Access Control System

2.4 Access Control Configuration

Tap Menu>Access Control to configure default verification mode, temporary authorization
mode, smoke sensor, door magnetism, closing delay, opening exception detection time, alarm
threshold and tamper alarm. Tap "Save" to finish configuration.
Default Verification Mode: Tap "Default Verification Mode" and select a verification mode
on the popup interface, options including "Face", "Card", "Face & Card" and "Face/Card".
Temporary Authorization Mode: Configure the authorization mode for different verification
modes. Tap "Temporary Authorization Mode" and select the mode(s) on the popup
interface, options including "Face", "Card" and "Face and Card". Tap "OK".
Smoke Sensor: Select "Close" or "Open", by default "Open".
Door Magnetism: Select "Close" or "Open", the default being "Close". When selecting
"Close", the door magnetism port SENS connects to the door magnetism switch NC port,
and GND to door magnetism COM port; when selecting "Open", the door magnetism port
SENS connects to the door magnetism switch NO port, and GND to door magnetism
COM port.
Closing Delay: Configure the delay time from door opening to door closing, the range
being 1~255 s, the default being 5 s.
Picture 2-10 Access control