Decommissioning And Cleaning - WAGNER GA 4000ACIC-R Translation Of The Original Operating Manual

Aircoat automatic spray gun
Hide thumbs Also See for GA 4000ACIC-R:
Table of Contents

Advertisement

VERSION 06/2013
OPERATING MANUAL
9.1

DECOMMISSIONING AND CLEANING

Cleaning agent in air duct!
Functional faults.
When cleaning, always operate the spray gun at at least 0.05 MPa; 0.5 bar; 7.25 psi
shaping air. No cleaning agent should be allowed to enter the air ducts.
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
Explosive atmosphere!
Explosive gases are produced when aluminum comes into contact
with halogenized hydrocarbons.
1. Relieve the pressure of gun and device.
2. Secure gun (remove the control air hose).
3. Connect the cleaning agent supply.
4. Dismount AirCoat nozzle and clean separately (see chapter 7.3).
5. Pressurize the cleaning agent supply to a maximum pressure of 4 MPa; 40 bar; 580 psi
and thoroughly fl ush the spray gun.
6. Relieve the pressure of gun and device.
7. Secure gun (remove the control air hose).
8. Clean outside of spray gun with a cleaning agent recommended by the lacquer
manufacturer and dry with a cloth or blow gun.
ORDER NUMBER DOC 2312956
NOTICE
DANGER
Never spray into a closed tank.
Ground the tank.
WARNING
To clean aluminum, do not use liquids containing halogenized
hydrocarbons.
40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga 4000acic-s

Table of Contents