Changing Aircoat Nozzle; Cleaning Aircoat Nozzle - WAGNER GA 4000ACIC-R Translation Of The Original Operating Manual

Aircoat automatic spray gun
Hide thumbs Also See for GA 4000ACIC-R:
Table of Contents

Advertisement

VERSION 06/2013
OPERATING MANUAL
7.3

CHANGING AIRCOAT NOZZLE

Defective AirCoat nozzle!
Insuffi cient paint application quality.
Do not use sharp-edged objects to treat carbide on the AirCoat nozzle.
Defective nozzle seal!
Product sprays into the air cap next to the nozzle.
Risk of contamination.
Do not clean the nozzle seal with sharp-edged objects.
Replace the nozzle seal if the sealing surface is damaged.
1. Relieve the pressure of gun and device.
2. Secure gun (remove the control air hose).
3. Unscrew union nut (A).
4. Remove air cap (B).
5. Press AirCoat nozzle (C) out of air cap (B) by hand and treat with cleaning agent until
all remaining paint has been dissolved.
6. Assembly:
Fit AirCoat nozzle (C) in nozzle seal (D).
7. Fit air cap (B) over nozzle (C).
Note the fl attened parts (X) on the nozzle and in the air cap.
8. Screw on union nut (A) and tighten by hand.
7.4

CLEANING AIRCOAT NOZZLE

For disassembly and assembly, see AirCoat nozzles section 7.3.
The AirCoat nozzle (C) can be placed into a cleaning solution which has been recommended
by the paint manufacturer.
ORDER NUMBER DOC 2312956
NOTICE
NOTICE
B
A
D
C
B_03056
X
B_03071
35