Doosan V158TI Operation & Maintenance Manual page 233

Hide thumbs Also See for V158TI:
Table of Contents

Advertisement

5
Gear number
Users can input the number of flywheel teeth in the engine to the controller so that the controller
can calculate the accurate RPM depending on the values of the pick-up sensor from the engine.
6
Starting fuel
Users can designate the amount of fuels used when the engine starts to operate and the operat-
ing current for the controller to activate the actuator changes based on these values.
7
Aux. speed
Users can adjust values to ensure safe operation of the engine based on the AUX signal values
when AUX is enabled.
8
Speed ramping
Users can input ratio values of speed changes when the speed increases or decreases in the
idle condition of the engine.
9
Max current
Users can designate the maximum operating current for the actuator of the engine.
10
Low battery
It measures the battery voltage supplied to the controller. When the measured values are lower
than the present voltage values, it will be alarmed. Usually, the acceptable battery voltage is
between 20 and 22V (without load).
11
Droop gain
Users can designate the droop values applicable to maximum load based on the current con-
sumption of the actuator.
12
F-load curr
Users can designate the maximum current values when the generator is in full load.
13
N-load curr
Users can designate the operating current values of the actuator when the generator has no
load.
- 45 -