Chapter 3
Identify the machine's flow switch configuration as shown in Figure 9 above.
1.
If the cable is coming out of the top of the flow switch, proceed to the Foot Switch section.
a.
If the cable is coming out of the bottom of the flow switch, proceed to the next step.
b.
Disconnect the flow switch cable from the machine's hydraulic valve.
2.
Install the 6" sense adapter cable (P/N 115-0172-218) between the flow switch cable connection and the
3.
machine's hydraulic valve.
Go to www.ravenhelp.com > Software Updates > Guidance and Steering > SmarTrax™ and
4.
SmarTrax™ RTK to download software version 6.0.41.
Follow the directions to update the SmarTrax software.
5.
In the field computer, select the CIH SPX 2240 2014 machine preset.
6.
Foot Switch
Foot Switch
FIGURE 10.
A factory-installed switch is located on the floor of the machine's cab. Use this foot switch to engage and
disengage the SmarTrax system after installation and calibration of the system is complete. Refer to the
SmarTrax and SmartSteer Calibration & Operation Manual (P/N 016-0171-277) for instructions on performing
the system calibration.
12