List Of Servo Parameter Initial Values; Basic Setting Servo Parameters Group ([Pr. Pa - Mitsubishi Electric MELSERVO-JET MR-JET-G-N1 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-JET MR-JET-G-N1 Series:
Table of Contents

Advertisement

7.6

List of servo parameter initial values

Basic setting servo parameters group ([Pr. PA_ _ ])

No.
Symbol
PA01
For manufacturer setting
PA02
**REG
PA03
*ABS
PA04
*AOP1
PA05
For manufacturer setting
PA06
*CMX
PA07
*CDV
PA08
ATU
PA09
RSP
PA10
INP
PA11
TLP
PA12
TLN
PA13
For manufacturer setting
PA14
*POL
PA15
For manufacturer setting
PA16
For manufacturer setting
PA17
For manufacturer setting
PA18
For manufacturer setting
PA19
*BLK
PA20
*TDS
PA21
*AOP3
PA22
**PCS
PA23
DRAT
PA24
AOP4
PA25
OTHOV
PA26
*AOP5
PA27
For manufacturer setting
PA28
**AOP6
PA29
For manufacturer setting
PA30
For manufacturer setting
PA31
For manufacturer setting
PA32
For manufacturer setting
PA33
For manufacturer setting
PA34
QDIS
PA35
For manufacturer setting
PA36
For manufacturer setting
PA37
For manufacturer setting
PA38
For manufacturer setting
PA39
For manufacturer setting
PA40
For manufacturer setting
PA41
For manufacturer setting
PA42
For manufacturer setting
PA43
For manufacturer setting
PA44
For manufacturer setting
Initial value
00003000h
00000000h
00000000h
00002000h
10000
1
1
00000001h
16
1600
1000.0
1000.0
00000000h
0
4000
1
00000000h
00000000h
000000ABh
00000000h
00000001h
00000000h
00000000h
00000000h
0
00000000h
00000000h
00000000h
0
0
0
00000000h
0.0
0
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
7.6 List of servo parameter initial values
Unit
pulse
%
%
%
0.1 rev
7 SERVO PARAMETERS
7
61

Hide quick links:

Advertisement

Table of Contents
loading