Servo Amplifier Setting Initialization; Initialization Procedure By Mr Mode Change - Mitsubishi Electric MELSERVO-JET MR-JET-G-N1 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-JET MR-JET-G-N1 Series:
Table of Contents

Advertisement

4.6

Servo amplifier setting initialization

Using the engineering tool (MR Mode Change packed with MR Configurator2) enables to initialize the setting of the servo
amplifier.
However, information related to the servo amplifier, including power-on cumulative time and the number of relays on/off, is not
initialized.
• The storage area of the servo amplifier has a limit for the number of writings. Do not use this function
frequently.
• Execute the initialization with the servo amplifier disconnected from the network and directly connected to
MR Mode Change via a USB cable.

Initialization procedure by MR Mode Change

Open MR Mode Change, and connect a servo amplifier and a personal computer with a USB cable. Turn on the servo
amplifier.
Servo amplifier
CN5
Confirm that "Reset to factory settings" is selected, and click "Write". After the writing is completed, cycle the power or reset
the software.
Cycling the power or resetting the software initializes the setting of the servo amplifier at startup. Confirm that the initialization
has completed by reading the settings from the servo amplifier.
Personal computer
USB cable
To USB
MR-J3USBCBL3M
connector
(option)
4 STARTUP
4.6 Servo amplifier setting initialization
4
39

Hide quick links:

Advertisement

Table of Contents
loading