[Pr. PN18_Communication error detection - Counter level (CERN)]
Initial value
9
Set the threshold until [AL. 086.1 Network receive data error (Network communication error 1)] is detected.
When "0" is set, this parameter is disabled.
If the PDO data is not updated with Sync0, the internal error counter will be added by 3 at a time.
When the PDO data is updated properly, the internal error counter is subtracted by 1.
Refer to the following for the example of the counter.
Receive (SM2) Event
1
Internal Error Counter
0
(Setting value = 9)
This servo parameter corresponds to [Sync Error Counter Limit (Obj. 10F1h: 02h)].
If the detection of [AL. 086.1] is disabled, the servo motor cannot be stopped at an occurrence of a communication error. In
addition, if the setting value is increased, it takes longer for the servo motor to stop at occurrence of a communication error.
Be careful when changing the set value as there is a danger of collision.