Likely cause
 The error warning indicator on the CCID (Charging Circuit Interrupting
Device) flashes.
Electrical leakage detection
function or self- diagnostic
function operates and power
is cut off
 Charging indicator does not illuminate, even though charging connector
is connected.
The plug is not properly con-
nected to the outlet
Charging connector is not
securely
connected
charging inlet
Hybrid battery (traction bat-
tery) is already fully charged
The
charging
equipment
does not operate
Correction procedure
When the voltage is insufficient, the error
warning indicator may flash when there is
noise interference. Perform a reset and con-
nect to a proper power source. (P. 118)
If charging does not start, immediately stop
charging and contact your Toyota dealer.
Check whether the plug is properly con-
nected to the outlet.
Check the connection status of the charging
connector.
• When connecting the charging connec-
tor, make sure not to touch the latch
release button. Insert the charging con-
nector securely until you hear a click. The
charging connector may not be connected
correctly if the latch release button is
pressed while inserting.
to
• After connecting the charging connector,
check that the latch release button is not
pressed and the charging indicator is
turned on.
If the charging indicator does not illuminate,
even though the charging connector is
securely connected, there may be a mal-
function in the system. Immediately stop
charging and contact your Toyota dealer.
When the hybrid battery (traction battery) is
fully charged, charging is not performed.
Please contact the facility manager when
there is a problem with charging equipment.
181
2-2. Charging