Toyota Prius Prime 2020 Manual page 118

Table of Contents

Advertisement

118
2-2. Charging
When a malfunction occurs during charging
The indicators on the CCID (Charging Circuit Interrupting Device)
use a combination of different statuses (not illuminated, illuminated
or flashing) to inform the user of internal malfunctions.
When the error warning indicator is illuminated or flashing, temporarily
remove the plug from the outlet and then reconnect it to check if the
error indicator turns off.
If the error warning indicator turns off, charging is now possible.
If it does not turn off, perform the correction procedure in the following
chart.
Status
Charging
system error
Plug
temperature
detection
malfunction
Plug
temperature
increase
detection
Charging
cable life
span notice
Charging
cable life
span
*
1
: When this occurs, charging is carried out without a limited charging current.
*
2
: When this occurs, charging is carried out with a limited charging current.
Error
Power
warning
indicator
indicator
Not
Not
illuminated
illuminated
or
illuminated
Illuminated
Flashes
Flashes
Flashes
Not
Flashes
illuminated
Illuminated
Flashes
Illuminated
Illuminated
Cause/Correction procedure
An
electrical
leakage
detected and charging is can-
celed, or there is a malfunction
in the charging cable.
 Consult your Toyota dealer
There is a malfunction in the
plug
temperature
*
1
part.
 Consult your Toyota dealer
An increase in the temperature
of the plug is detected due to an
improper connection between
*
the outlet and plug.
 Check that the plug is
securely connected to the
outlet.
The number of charges using
the charging cable is nearing
the end of its usable life span.
 Consult your Toyota dealer
The number of charges using
the
charging
cable
exceeded its usable number of
charges.
 Consult your Toyota dealer
is