Electrical Guidelines

WARNING – Be sure to disconnect the power supply before servicing any electrical components.

Electrical Requirements

With the exception of the Traditional series, a single gang outlet (120v 15-amp 60hz) must be provided in the location
where the gas and electrical components will be placed, which must be within 36" of the pilot (see diagram in "Gas
Requirements and Setup" for visual). An AC Adapter is provided with all Ortal fireplaces to connect the electrical
receiver to the outlet. Electrical work should be done by a qualified licensed electrician, per local code.

Electrical Requirements for Traditional Series

The gas and electrical components on a Traditional series Ortal fireplace are located in a control box on the left side
of the fireplace where a single gang outlet (120v 15-amp 60hz) is provided. See the section labelled "Routing the Gas
Line for Traditional Series" for a visual. Electricity must be supplied to this outlet by a qualified licensed electrician,
per local code. An AC Adapter is provided with all Ortal fireplaces to connect the electrical receiver to the outlet.

TV/Electronics Electrical Wires

When running wires for electronics (such as a TV) through the fireplace chase, it is recommended to wrap wires in a
thermal insulating wrap (R-6) as shown in diagram below: