  • Page 1 ORTAL STAND ALONE FIREPLACES: SPECIFICATIONS & PRODUCT GUIDE...
  • Page 2 1. NOTES The appliance must be installed in accordance with the ORTAL AU/NZ Installation Manual. The appliance must be properly connected to an approved chimney venting system. Refer to the specific appliance installation guide to determine vent size and pathway requirements. In addition, adhere to the following pre- installation guidelines: •...
  • Page 3: Specifications

    2. SPECIFICATIONS MODEL BURNER INJECTORS NOMINAL GAS INLET MANIFOLD TURNDOWN FLUE SIZE TYPE CONSUMPTION PRESSURE PRESSURE PRESSURE Marked 650: with 26MJ/h 1.13kPA 0.82kPA 0.23kPA 107/164mm 7x0.950mm orifice B100 Marked 1200: with 37MJ/h 0.69kPA 0.73kPA 0.26kPA 125/205mm 7x1.275mm orifice B135 Marked 1200: with 55MJ/h 1.13kPA 0.61kPA...
  • Page 4: Clearance To Combustible Surfaces

    3. CLEARANCE TO COMBUSTIBLE SURFACES 915mm 915mm 150mm 150mm 1016mm 300mm 300mm FRONT VIEW SIDE VIEW Back wall must be non-combustible. We recommend 16mm Gypsum or equivalent. (NOTE: For front facing Stand Alone models, gas cmponents are located on the right side hidden by the access panel.) 150mm 150mm Min 1016mm...
  • Page 5 4. SPECIFICATIONS FRONT VIEW SIDE VIEW TOP VIEW FRONT FACE GAS CONNECTION MODEL DIMENSIONS 1106 1319 1502 1694 OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 5...
  • Page 6 75 STAND ALONE SCREEN OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 6...
  • Page 7 75 STAND ALONE SCREEN OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 7...
  • Page 8 75 STAND ALONE SCREEN OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 8...
  • Page 9 110 STAND ALONE 1319 OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 9...
  • Page 10 110 STAND ALONE OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 10...
  • Page 11 110 STAND ALONE OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 11...
  • Page 12 150 STAND ALONE SCREEN OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 12...
  • Page 13 150 STAND ALONE SCREEN OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 13...
  • Page 14 150 STAND ALONE SCREEN OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 14...
  • Page 15 5. INSTALLATION - TIMBER 1. Position the unit at the desired height and mark the wall. Unit should have a minimum 300mm and maximum 750mm distance from the bottom of the unit to the floor. 2. Create an opening in the wall big enough to position the 4x8 blocks between the wood studs at the desired height. 3.
  • Page 16 6. INSTALLATION - CONCRETE Concrete Wall Mounting Detail Sketch 1 9.5mm Min. 300mm – Max.750mm OBLICA | SPECIFICATIONS AND PRODUCT GUIDE PAGE 16...
  • Page 17 7. TESTING THE ORTAL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN TESTED AND APPROVED BY AGA & IAPMO-R&T FOR USE WITH NATURAL GAS (NG). Australian Standard AS5263-0:2016 - Decorative Gas Log and Other Fuel Effect Appliances Patent Pending for screen barrier glass bracket: USSN 60/040,074...