Minimum Firebox Clearances Diagram

The following diagram shows the minimum clearances to the sides and back of any built-in Ortal fireplace.
LEGEND:
Non-combustible material such as 5/8"
Type X fire rated drywall (or equivalent)
Combustible material
NOTES:
The clearances mentioned in the diagrams on the immediately previous page apply to the front of the
firebox.
The 12" clearance spans from the top of the fireplace viewing area to the bottom of the framing.
The 9-13/16" clearance spans from the bottom of the legs to the bottom of the fireplace viewing area. Legs
are not removable or adjustable.
While not shown in this diagram, a heat release is required for all built-in Ortal fireplaces (see section
labeled "Heat Release" details). An air intake is also required for all built-in Ortal fireplaces with the double
glass heat barrier (see section labeled "Air Intake" details).
No building material is permitted to touch the vent pipe. Only tested, listed and approved components are
permitted to touch the pipe.
Ortal Installation Manual: Built-in Models, December 2019 (V2)
Wood framing
Metal framing
25