Hydraulic Reservoir - Fluid Change - Fayat Dynapac CC900G Instruction Manual

Vibratory roller
Table of Contents

Advertisement

Fig. Hydraulic reservoir
1. Draining
2017-07-10

Hydraulic reservoir - fluid change

Use an external drainage pump when
draining/emptying the hydraulic reservoir.
1
Unscrew the reservoir cap. Use an external pump and
check that the pump's hose reaches the bottom of the
hydraulic reservoir in order to remove as much of the
oil as possible. Drain the hydraulic oil into a drainage
container.
Change the hydraulic fluid filter, see under heading
'Every 900 hours of operation'.
Fill with fresh hydraulic fluid (see under Lubricants
heading for the correct grade), refit the filler cap, and
check the level in the tank.
Wipe up any spillage.
Start the engine and operate the various hydraulic
functions. Check the level in the reservoir and top off
as required.
4812274432.pdf
Maintenance - 2000h
Danger of being burned when draining hot oil.
Danger of being burned when draining hot oil.
Wear gloves and eye protectors.
Wear gloves and eye protectors.
Use a receptacle that holds at least 15 liters (4
Use a receptacle that holds at least 15 liters (4
gal).
gal).
Collect the oil and deliver to special waste
Collect the oil and deliver to special waste
handling.
handling.
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents