Allocation of bit position for monitoring the CN1-29, 30 output signal.
Pn86A.0
0 ~ 7
Enables or disables the allocated bit position for monitoring the CN1-29, 30
output signal.
Pn86A.1
0
1
Pn86A.2
Pn86A.2
■Monitor Information
Bit
IO_STS1
D24 ~ D31
IO_STS8
SVCMD_IO (I/O signal monitor) Bit Position Allocation
Same settings for the CN1-1, 2 output signal
Disabled
Enabled
Reserved (Do not change)
Reserved (Do not change)
Name
Monitors the CN1 output signal
Indicates the status of the CN1 output signal.
Use any of the Pn868, Pn869 and Pn86A to allocate bit positions for monitoring
the CN1 output signal.
When using these parameters, if the same bit position is allocated to more than
two signals, the logical OR operator is used to send a signal.
Description
Value
I/O Status
0
OFF (Output transistor is open.)
1
ON (Output transistor is closed.)