Term
Safe BaseBlock Function
(SBB function)
Safe BaseBlock with Delay
Function (SBB-D function)
Safe Position Monitor with
Delay Function
(SPM-D function)
Safely Limited Speed with
Delay Function
(SLS-D function)
Safe (HWBB) state
Safe State
Deceleration Monitoring
Position Monitoring
Constant-speed Monitoring
Safety-related Module
Parameter
Safety-related Servo
Parameter
System Reset
Parameter Recalculation
Proof Test
Axis A
Axis B
This is one of safety functions in the Safety Module.
This is the safety function that is equivalent to the Safe Torque Off function defined
in IEC 61800-5-2.
This is one of safety functions in the Safety Module.
This is the safety function that is equivalent to the Safe Stop 1 function defined in
IEC 61800-5-2.
This is one of safety functions in the Safety Module.
This is the safety function that is equivalent to the Safe Stop 2 function defined in
IEC 61800-5-2.
Stopping function in the Safety Module.
This is the safety function that is equivalent to the Safely-Limited Speed function
defined in IEC 61800-5-2.
The Safety Module is shutting OFF power supply to the motor by executing the
HWBB function of SGDV/SGD7S or SGD7W SERVOPACK.
Safe state depends on safety functions used.
SBB function
Safe (HWBB) state
SBB-D function
Safe (HWBB) state
SPM-D function
When monitoring positions or in a safe (HWBB) state
When monitoring constant-speed operation or in a safe (HWBB)
SLS-D function
state
The Safety Module is monitoring deceleration operation of the motor.
The Safety Module is monitoring distance that the motor moved.
The Safety Module is monitoring constant-speed operation of the motor.
Parameter related to the safety functions of the Safety Module.
These parameters contain the information related to the safety functions of
SERVOPACKs and servomotors, and are managed by the Safety Module.
Reset the servo system by shutting OFF the power or executing software reset
(Fn030).
Recalculation of parameter by CONFIG command via MECHATROLINK-III or by the
request from the Command Option Module.
Scheduled tests defined in IEC 61508-4.
This is the test that is used to detect the failure of the safety-related system.
In this manual, the axes are called axis A and axis B.
However, they are displayed as "axis 1," "axis 2," "AXIS#00," or "AXIS#01"
on the Engineering Tool.
Meaning
900-200-100
18/57