Calibrating the drive plate and controller

General

IMPORTANT! Calibrate the drive plate and controller:
-
-
-
Failure to calibrate the drive plate and the controller will lead the power source to select the
factory defaults. This may lead to unsatisfactory welding results. Calibrating the drive plate
and controller.
Calibrating the
1
drive plate and
2
controller
3
The right-hand display on the power source shows „---"
4
The left-hand display on the power source shows „St1"
5
Danger of injury due to rotating gears and drive components.
Operating the equipment incorrectly can cause serious injury and damage.
► Do not touch rotating gears or rotating components of the drive plate.
6
The PushPull unit calibration process is finished when the displays show the values „PPU"
and „---".
30
before commissioning
each time you replace the drive plate
after every wire feeder software update
Attach the power source mains lead to the mains
Set the mains switch on the power source to position „I"
Select function „PPU" in the second level of the power source menu, as described in
the power source operating manual
Press the inching in key
Decouple the drive plate - the wire feeder drive must be unstressed
CAUTION!
Press the inching in key
The wire feeder drive is calibrated in unstressed state. During calibration the righthand
display on the power source shows „run"