Safety Inspec-
The operator is required to have the LaserHybrid head tested by an electrician
tion
after every alteration, installation or modification, and all repairs and mainten-
ance, and at least every 12 months, to ensure that it is in its correct state.
Regulation
IEC (EN) 60 974-1
BGV A2, Section 5
BGV D1, Sections
33 / 49
VDE 0701-1
VDE 0702-1

Modifications

Do not carry out any alterations, installations, or modifications to the LaserHy-
brid head without first obtaining the manufacturer's permission.
Parts that are not in perfect condition must be replaced immediately.
Spare and Wear-
Use only original spare and wearing parts (also applies to standard parts).
ing Parts
It is impossible to guarantee that externally procured parts are designed and
manufactured to meet the demands made on them, or that they satisfy safety
requirements.
When ordering, specify the exact name and part number according to the Spare
Parts List as well as the serial number of your device.
Calibrating
Regular calibration of power sources is required in accordance with international
Power Sources
standards. The manufacturer recommends a calibration interval of 12 months.
Please contact your service center if you require further details.

The CE label

The LaserHybrid head meets the basic requirements of the Low Voltage and
Electromagnetic Compatibility Directives and therefore has CE sign.

Copyright

Copyright of these Operating Instructions remains with the manufacturer.
Text and illustrations were accurate at the time of printing. Fronius reserves the
right to make changes. The contents of the Operating Instructions shall not
provide the basis for any claims whatsoever on the part of the purchaser. If you
have any suggestions for improvement, or can point out any mistakes that you
have found in the Operating Instructions, we will be most grateful for your com-
ments.
Title
Equipment for Arc Welding, Part 1: Welding Current
Sources
Electrical Plants and Equipment
Welding, Cutting and Related Work Methods
Repairing, Modifying and Testing Electrical Devices;
General Requirements
Repeating Tests on Electrical Devices