List Of Events - COBHAM EXPLORER 5075GX Installation And User Manual

Auto-deploy antenna system
Hide thumbs Also See for EXPLORER 5075GX:
Table of Contents

Advertisement

List of events

B.2
List of events
Error
Severity
code (ID)
08065-0 WARNING GNSS data
08067-0 ERROR
0806A-0 WARNING VMU connection
0806C-0 ERROR
0806E-0 ERROR
08078-0 WARNING VMU TX frequency
08107-0 ERROR
0810A-0 ERROR
0810C-0 ERROR
0810D-0 ERROR
08800-0 ERROR
08840-0 WARNING Master PLL lock
08841-0 ERROR
08842-0 WARNING GSC demodulator
08843-0 WARNING DVBS demodulator
B-8
Description
PCB temperature
VMU frequency setup
VMU 10 MHz reference The VMU Rx or Tx reference signal is not present.
invalid
ADM FPGA load
ADM production data
File system integrity
Antenna communication Link to the ACU could not be established. Either the
Internal power supply
Tuner lock
Table B-1: Event messages
Appendix B: System messages
Explanation
Missing GPS data (fix).
ADM temperature too high. The ACU is not equipped
with a fan, so make sure there is compliance with the
environmental specifications.
The ACU has lost connection with the sat modem.
There is a mismatch in the frequency setup. Probably
the sat modem is not configured correctly to match the
requirements of the ACU and antenna. A common
mismatch is the absence of Rx or Tx LO parameter in
the VSAT modem.
Whether this error Rx or Tx reference, depends on the
users selection on the modem profile page. Make sure
VMU Rx/Tx cable is connected and that the VMU is
configured to output the RX/TX reference signal.
VSAT modem unit provided a TX frequency of zero.
This may degrade tx performance. To remove this
warning re-configure the modem to provide the correct
tx frequency.
The ADM FPGA cannot be initialised and loaded.
Production data has been corrupted.
One or more file system partitions are corrupt. You may
have lost your settings and collected statistics. If
restarting the system does not help, contact your
service partner.
ACU is malfunctioning, or - if the system software has
just been updated - the software is too old and is not
compatible with the ACU hardware.
An internal power supply voltage is outside its legal
range.
The master PLL has lost lock. Check the input reference
signal.
The internal tuner PLL was unable to lock.
The GSC demodulator has reported an error.
The DVBS demodulator cannot be initialised and loaded
correctly.
98-143492-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EXPLORER 5075GX and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents