12.2 Safety Instructions

Before starting mounting/installation work, you must read and observe the instruction manuals and
l
the safety instructions that they contain for the drive and motor that you are using in your application.
This manual is only valid in conjunction with the instruction manuals for the drive and motor you are
l
using in your application.
Mount the motor choke on a conductive earthed plate in the switchgear cabinet.
l
The choke can become hot during operation (rising to temperatures in excess of 80°C). Therefore,
l
you should make sure that the choke is mounted a sufficient distance away from neighboring com-
ponents.
Provide the requisite conditions for unobstructed convection to cool the choke.
l
A connection diagram appears in the drive instructions manual.
l
If the motor cable is longer than 25 m, then the motor choke is wired into the cable close to the amp-
l
lifier. When laying the motor cable, allow about 400 mm for the connection to the choke.

12.3 Type Assignment

Drive*
AKD-x003x to AKD-x006x
AKD-x012x
AKD-x024x
AKD2G-xxx-xV003 to -xV006
AKD2G-xxx-xV012
S701 to 724
S748/772
*AKD part numbers indicate continuous current rating (-003 is 3 A, -012 is 12 A, etc).
AKD2G/AKD/S700 Accessories Manual | 12   Motor Chokes
Motor choke
Approvals
3YLN-06
CE, UL
3YLN-14
CE, UL
3YLN-24
CE, UL
3YLN-06
CE, UL
3YLN-14
CE, UL
3YLN-xx
CE, UL
Not required
Kollmorgen™ | kdn.kollmorgen.com | November 2019
Condition
Motor cable > 25m
Motor cable > 25m
Motor cable > 25m
Motor cable > 50m
Motor cable > 50m
Motor cable > 25m