Order Codes - Kollmorgen AKD 2G Accessories Manual

Table of Contents

Advertisement

10.2 Order Codes

The KCM modules may only be connected to drives with 400/480 V rated voltage.
Type/Order Code
KCM-S200-0000
KCM-P200-0000
KCM-E200-0000
KCM-E400-0000
Technical Data
Type
Storage
Capacity
[Ws]
KCM-S200
1600
KCM-P200
2000
KCM-E200
2000
KCM-E400
4000
AKD2G/AKD/S700 Accessories Manual | 10   Capacitor Modules
Remarks
Energy Saving Module, 1.6 kWs
Power Module, 2 kWs
Expansion Module 2 kWs
Expansion Module 4 kWs
Rated
Peak
supply
supply
voltage
voltage
[V=]
[V=]
max 850 VDC
max 950 VDC
(30s in 6min)
Kollmorgen™ | kdn.kollmorgen.com | November 2019
Power
Protection
Inception
[kW]
Class
voltage
18
IP20
calculated
470 VDC
Weight'
[kg]
[V=]
6,9
6,9
-
4,1
-
6,2
41