Download Print this page

Kinroad 150 Service Manual page 64

Advertisement

KINROAD 150 SERVICE MANUAL
Connect the positive cable first, and then connect the negative cable.
BATTERY OPEN-CIRCUIT VOLTAGE INSPECTION
Disconnect the cable on the battery terminals.
Disconnect the negative pole first, and then the positive pole.
Measure the voltage between the two poles of the battery.
BATTERY CHARGING
Lift the battery out of the vehicle.
Connect the positive pole of the charger with the positive pole of the battery.
Connect the negative pole of the charger with the negative pole of the battery.
Charge the battery for the charging time marked on the battery.
Do not use fast charging unless it is emergent.
No smoking or open fire near the battery when charging.
At the beginning or the end of charging, turn off the charger first to avoid the connecting part
arcing.
Measure the voltage 30 minutes after charging is finished, and it should reach the specified value;
otherwise it needs recharging.
Charging current
Charging time
Charging result
PRIMARY COIL
Full charging
Under charging
Normal
Fast
Normal
Fast
13.1V
12.3V
0.7A
3.0A
5-10 hours
30 minutes
Open-circuit
>=12.8V
65
VERSION 1, DEC., 2005
voltage

Advertisement