8 Communication
Option Low Priority Alarm Codes
These codes are transmitted as Manufacturer Specific Diagnostic low priority alarms that can be seen in the PLC
configuration software. These low priority codes are the same codes that appear in the drive manual, except with an offset
of 0x1000.
Drive Alarm
Code
(hex)
<1>
0401
Undervoltage (Uv)
0402
Overvoltage (ov)
0403
Heatsink Overheat (oH)
0404
Drive Overheat (oH2)
0405
Overtorque 1 (oL3)
0406
Overtorque 2 (oL4)
0407
Rum Command Input Error (EF)
0408
Drive Baseblock (bb)
0409
External Fault 3, input terminal S3 (EF3)
040A
External Fault 3, input terminal S4 (EF4)
040B
External Fault 3, input terminal S5 (EF5)
040C
External Fault 3, input terminal S6 (EF6)
040D
External Fault 3, input terminal S7 (EF7)
040E
External Fault 3, input terminal S8 (EF8)
040F
Cooling Fan Error (FAn)
0410
Overspeed (oS)
0411
Excessive Speed Deviation (dEv)
0412
PG Disconnected (PGo)
0414
MEMOBUS/Modbus Comm. Error (CE)
0415
Option Communication Error (bUS)
0416
Serial Comm. Transmission Error (CALL)
0417
Motor Overload (oL1)
0418
Drive Overload (oL2)
041A
Option Card External Fault (EF0)
041B
Motor Switch Command Input during Run (rUn)
041D
Serial Comm. Transmission Error (CALL)
041E
Undertorque Detection 1 (UL3)
041F
Undertorque Detection 2 (UL4)
<1> Drive error code is stored in MEMOBUS/Modbus address 0080 hex.
<2> Not available in V1000-series drives.
38
Table 25 PROFINET Option Low Priority Alarm Codes
Description
<2>
<2>
YASKAWA SIEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Technical Manual
Drive Alarm
Code
(hex)
<1>
0420
MEMOBUS/Modbus Test Mode Fault (SE)
0422
Motor Overheat (oH3)
0427
PID Feedback Loss (FbL)
0428
PID Feedback Loss (FbH)
042A
Drive Disabled (dnE)
042B
PG Disconnected (PGo)
0431
Option Watchdog Error (E5)
0432
Option Station Address Setting Error (AEr)
0433
Option Comm. Cycle Setting Error (CyC)
0434
High Current Alarm (HCA)
0435
Cooling Fan Maintenance Time (LT-1)
0436
Capacitor Maintenance Time (LT-2)
0438
Option EEPROM Error (EEP)
0439
External Fault (input terminal S1) (EF1)
043A
External Fault (input terminal S2) (EF2)
043B
Safe Disable Input (HbbF)
043C
Safe Disable Input (Hbb)
043D
Mechanical Weakening Detection 1 (oL5)
043E
Mechanical Weakening Detection 2 (UL5)
043F
PLC Alarm (PA1)
0440
PLC Alarm (PA2)
0441
Output Voltage Detection Fault (voF)
0442
IGBT Maintenance Time (90%) (TrPC)
0443
Soft Charge Bypass Relay Maintenance Time (LT-3)
0444
IGBT Maintenance Time (50%) (LT-4)
0445
Braking Transistor Overload (boL)
0448
Motor Overheat (NTC Input) (oH5)
0449
DriveWorksEZ Alarm (dWAL)
Description
<2>

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profinet si-ep3

Table of Contents