8 Communication
Option High Priority Alarm Codes
These codes are transmitted as Manufacturer Specific Diagnostic high priority alarms that can be seen in the PLC
configuration software. These high priority codes are the same codes that appear in the drive manual, except with an
offset of 0400 (hex).
Drive Alarm
Code
Description
(hex)
<1>
1000
None
1001
DC Bus Fuse Open (PUF)
1002
DC Bus Undervolt (Uv1)
1003
CTL PS Undervolt (Uv2)
1004
MC Answerback (Uv3)
1005
Short Circuit (SC)
1006
Ground Fault (GF)
1007
Over Current (oC)
1008
DC Bus Overvolt (oV)
1009
Heatsink Overtemp (oH)
100A
Heatsink Max Temp (oH1)
100B
Motor Overload (oL1)
100C
Inv Overload (oL2)
100D
Overtorque Det 1 (oL3)
100E
Overtorque Det 2 (oL4)
100F
DynBrk Transistor (rr)
1010
DynBrk Resistor (rH)
1011
External Fault 3 (EF3)
1012
External Fault 4 (EF4)
1013
External Fault 5 (EF5)
1014
External Fault 6 (EF6)
1015
External Fault 7 (EF7)
1016
External Fault 8 (EF8)
1017
Heatsink Fan (FAn)
1018
Overspeed Det (oS)
1019
Speed Deviation (dEV)
101A
PG Open (PGo)
101B
Input Phase Loss (PF)
101C
Output Phase Loss (LF)
101D
None
101E
Operator Disconnected (oPr)
101F
EEPROM R/W Error (Err)
1020
None
36
Table 24 PROFINET Option High Priority Alarm Codes
Output Transistor Failure. Replace the drive
Input power fluctuation too large
Cycle drive power and replace drive if fault continues
Cycle drive power and replace drive if fault continues
• Check drive wiring
• Cycle drive power and replace drive if fault continues.
Check for motor and/or cable damage
Check motor, motor load and accel/decel rates
• Check incoming voltage
• Check deceleration time
• Check ambient temperature
• Check drive cooling fan
Check drive cooling fan
• Check the load, accel/decel and cycle times
• Check motor rated current (E2-01)
• Check the load, accel/decel and cycle times
• Check drive rating
• Check L6-02 and L6-03 settings
• Check system mechanics
• Check L6-05 and L6-06 settings
• Check system mechanics
Cycle drive power and replace drive if fault continues
Check load, operating speed and deceleration time
• Multifunction digital input set to external fault
• Circuit at terminal is closed
<2>
Check drive cooling fan
• Check reference and reference gain
• Check F1-08 and F1-09 settings
• Check load, accel/decel times and system mechanics
• Check F1-10 and F1-11 settings
Check PG card connections
<2>
Excessive input voltage fluctuation
• Check for broken wire/loose terminals
• Check motor rating
Reconnect the digital operator
Cycle drive power and replace drive if fault continues
-
Corrective Action
YASKAWA SIEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Technical Manual
-
-