A write request is first sent containing the parameter request.
If the write request is valid, the SI-EP3 acknowledges it with request accepted. The master then sends a read request. If
the SI-EP3 is still busy performing the internal parameter request, it will return a negative response with the error code
"0xB5" (State conflict). In this case, the master repeats the read request until the SI-EP3 has the PROFIdrive compatible
response data ready.
If the write request is invalid, a negative response is returned with an error code.
Base Mode Parameter Access - Local
The DO-ID field in the Record Data Object request header is not evaluated by the parameter manager. Parameters can be
read through any slot in the configuration.
Byte
ErrorCode
ErrorDecode
ErrorCode1
ErrorCode2
Error class
0...9
10 (0x0A)
11 (0x0B)
12 (0x0C)
13...15
Read block is used in read requests and responses. Write block is used in write requests and responses. The request
consists of unique identifiers for the connection, addressing information and length of the record data. The response also
contains two additional fields for transferring information.
YASKAWA SIEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Technical Manual
Table 17 Response Error Codes
0xDF (Error Write)
0xDE (Error Read)
0x80 (PNIORW) ErrorCode1 decoded according to
0x81 (PNIO) ErrorCode1 and ErrorCode2 decoded according to
Error class and error code (Refer to
Not described
Table 18 ErrorCode1 with PNIORW Decoding
Meaning
(Reserved)
Application
Access
Resource
User-specific
Value and Meaning
Table
18).
0 = Read error
1 = Write error
2 = Module failure
3...7 = Reserved
8 = Version conflict
9 = Feature not supported
10...15 = User-specific
0 = Invalid index
1 = Write length error
2 = Invalid slot
3 = Type conflict
4 = Invalid area
5 = State conflict
6 = Access denied
7 = Invalid range
8 = Invalid parameter
9 = Invalid type
10...15 = User-specific
0 = Read constraint conflict
1 = Write constraint conflict
2 = Resource busy
3 = Resource unavailable
4...7 = Reserved
8...15 = User-specific
8 Communication
Table
18. ErrorCode2 is 0.
Table
18.
Error Code
-
-
31